Prototype build notes
An illustrated build guide for the original GreenBox, from cutting the frame and mounting the plates to documenting the wiring and calculating the field.
High voltage. Build the frame with all electrical equipment disconnected. The original prototype operates at kilovolt-level voltages, and its capacitor and wiring can retain charge after switch-off. A qualified person with high-voltage experience should review the circuit and enclosure, complete the electrical installation, and verify that the plates are de-energized before anyone handles them or changes a sample. Electrical Safety Manual (SLAC)

Parts and tools
| Mechanical parts | Prototype dimensions or quantity |
|---|---|
| Spruce slats, 18 × 44 mm | Eight at 29 cm and two at 26 cm |
| MDF panels | 2.5 mm thick, cut to fit the top and bottom |
| Plain steel plates | Two at 20 × 25 cm. The original build specified 2 mm sheet and listed 1–1.5 mm as alternatives. |
| Acrylic sheet | A4, 2 mm thick |
| Glass Petri dishes | 75 mm diameter × 15 mm high |
| Assembly hardware | Steel washers, screws, wood glue, clamps, rubber feet, and a rear junction box |
| Electrical parts and tools | Original prototype |
|---|---|
| High-voltage generator | 10 kV module |
| Capacitor | 1 nF, rated 20 kV |
| Resistor | 1 MΩ, rated 20 kV |
| Wiring and hardware | 20 kV high-voltage cable, separate return/earthing lead, ring terminals, blind rivets, banana plugs, and voltage warning labels |
| Bench equipment | Variable DC bench supply (HANMATEK HM310T), soldering station, multimeter, and a compatible high-voltage probe |


Assemble the frame and plates
- Cut the spruce. From the 18 × 44 mm slats, cut eight pieces to 29 cm and two pieces to 26 cm.

- Make four L-shaped supports. Glue the 29 cm pieces in pairs to form four L-shapes. Clamp each pair until the glue sets.
- Drill the crosspieces. Mark the centre of each 26 cm slat and drill a 5 mm hole. In the original build, these holes were used as rear cable passages.
- Assemble the frame halves. Attach two L-shaped supports to each crosspiece. Keep the two halves square and aligned so they can form the top and bottom of the frame.

- Prepare the steel plates. Cut two 20 × 25 cm plates, drill the 4 mm mounting holes shown in the drawing, and deburr the edges and holes.

- Fit the plates. Screw one plate into each frame half at the corners. Dry-fit the halves with the plates facing each other and check that they are parallel. The original build had a 48 mm gap between the plate faces. If the prototype will be wired, complete the plate-lead work described in step 1 of the electrical section before closing the frame.
- Join the frame halves. Once the plate fit and any plate-lead work are complete, glue the halves together and clamp them until the glue sets.

- Fit the MDF panels. Mark and cut the top and bottom panels from the 2.5 mm MDF sheet, then glue them to the frame.
- Add the feet and junction box. Fit a rubber foot at each corner of the bottom panel for stability. Mount the junction box at the back of the top panel. The feet, wood, and MDF serve mechanical purposes. Electrical protection requires a suitably rated enclosure, insulation and cable entries.

Install the field generator and wiring
The steps below document the original wiring. The photographs show the prototype as built. Have the wiring diagram, protective enclosure, earthing, and stored-charge protection reviewed before making or powering these connections.
- Connect the plate leads before closing the frame. The original build attached the red high-voltage lead to the lower plate and the return lead to the opposite plate. It used a ring terminal and blind rivet at each plate and brought the leads through the rear crosspieces. Use connections and feedthroughs approved for the reviewed design.

- Mount the generator in the rear enclosure. The original build placed the 10 kV module in the rear box. The reviewed mounting arrangement needs to secure the module and keep live parts inaccessible.
- Wire the high-voltage side. The original arrangement placed the 20 kV, 1 nF capacitor across the generator output and the 20 kV, 1 MΩ resistor in the lead from the high-voltage output to the red plate. The opposite plate was the return/reference plate. The series resistor does not provide a discharge path across the capacitor. The reviewed circuit needs a dedicated means of discharging stored energy, with the return and any protective earth identified separately on the wiring diagram.

- Connect the DC supply to the module input. The prototype used banana plugs at the bench supply and soldered leads at the generator input. The original notes list a maximum of 12 V for that particular module and a bench current limit of 0.4 A. Confirm the actual module’s input rating from its documentation. The bench supply’s input-side current limit does not establish a safe output or touch current on the high-voltage side.

- Inspect and commission the assembled unit. Before applying power, have a qualified person check the enclosure, insulation, separation between conductors, cable strain relief, earthing where applicable, and the means of discharging stored energy. Keep the plate area inaccessible while energized. Before opening the enclosure or handling a sample, isolate the supply and have the absence of voltage verified using the procedure and equipment specified for the reviewed setup.
Measure voltage and estimate field strength
Measure the voltage difference between the plates only with a suitable high-voltage probe and meter, using the setup’s approved measurement procedure. The probe ratio and meter compatibility determine how to interpret the reading. With a compatible 1000:1 probe, a reading of 3.7 V represents 3.7 kV between the measurement points.
For the original 48 mm plate gap, the ideal parallel-plate model gives 3,700 V ÷ 4.8 cm ≈ 770 V/cm. The following values are calculation examples for that gap.
| Nominal field | Calculated plate voltage |
|---|---|
| 750 V/cm | 3.60 kV |
| 1,250 V/cm | 6.00 kV |
| 1,500 V/cm | 7.20 kV |
Use the E-Field Calculator to recalculate the nominal field for a different spacing or voltage.